Showing posts with label water. Show all posts
Showing posts with label water. Show all posts

Saturday, November 1, 2014

Automatic detectors water tank pump circuit

This is a circuit detectors on the water pump. This circuit works automatically when the water is discharged to storage tanks or redundant. If the storage tank water runs out then the circuit will work running the pump, and an excess of water this circuit will automatically stop the pump working. Below the detection circuit:

Automatic
Automatic detectors water tank pump schematic diagram

R1                   10K ohms resistor
R2                   10K ohms resistor
R3                   10K ohms resistor
R4                   1K ohms resistor
R5                   10K ohms resistor
R6                   1K ohms resistor
C1                   100nF cap
Led1                5mm green led
Led2                5mm red led
D1                   4V7 zener diode
Piezo               Piezo HPE-120
VR1                78L05 regulator
IC1                  12F683 SOIC microcontroller from Microchip
S1                    Push button
Others:
Box
9V battery
PCB
Metal strips
Hex program for the microcontroller
Read More..

Thursday, September 4, 2014

Water level alarm circuit


Here is a simple water level alarm schema that will produce an audible alarm when the water level reaches a preset level.The schema can be powered of a 3V battery and is very handy to use.





The schema is based on an astable multivibrator wired around IC1 (NE 555).The operating frequency of the astable multivibrator here will depend on capacitor C1, resistances R1,R2 and the resistance across the probes A&B.When there is no water up to the probes,they will be open and so the multivibrator will not produce oscillations and the buzzer will not beep.When there is water up to the level of probes,some current will pass through the water,the schema will be closed to some extend,and the IC will start producing oscillations in a frequency proportional to the value of C1,R1,R2 and the resistance of water across the probes.The buzzer will beep to indicate the presence of water up to the level of the sensing probes.




Notes.

* The schema can be powered of a 3V battery.
* Assemble the schema on a good quality PCB or common board.
* The probes can be made of two insulated copper Aluminiun wires.
* Place the probes at the position where you have to sense the leve

Read More..

Water Level Indicator Circuit

Simple, two-wire, remote monitoring unit, Three-LED level display, 9V battery powered
The whole project was developed on a friends request. Its purpose was to remotely monitor the water-level in a metal tank located in the attic by means of a very simple control unit placed in the kitchen, some floors below.

Mains requirements were:
  1. No separate supply for the remote schema
  2. Main and remote units connected by a thin two-wire cable
  3. Simple LED display for the main unit
  4. Battery operation to avoid problems related to mains supply and water proximity
  5. As the schema was battery operated a low current consumption was obviously welcomed
The very small remote unit is placed near the tank and measures the water level in three ranges by means of two steel rods. Each range will cover one third of the tank capacity:
  • Almost empty - signaled by means of a red LED (D3) in the control unit display
  • About half-level - signaled by means of a yellow LED (D2) in the control unit display
  • Almost full - signaled by means of a green LED (D1) in the control unit displa
Circuit diagram:
Water
Water-level Indicator Circuit Diagram

Circuit operation:
When the water-level is below the steel rods, no contact is occurring from the metal can and the rods, which are supported by a small insulated (wooden) board. The small schema built around IC1 draws no current and therefore no voltage drop is generated across R5. IC2A, IC2B and Q1 are wired as a window comparator and, as there is zero voltage at input pins #2 and #5, D3 will illuminate. When the water comes in contact with the first rod, pin #13 of IC1 will go high, as its input pins #9 to #12 were shorted to negative by means of the water contact. Therefore, R4 will be connected across the full supply voltage and the remote schema will draw a current of about 9mA. 

This current will cause a voltage drop of about 0.9V across R5 and the window comparator will detect this voltage and will change its state, switching off D3 and illuminating D2. When the water will reach the second rod, also pin #1 of IC1 will go high for the same reason explained above. Now either R3 and R4 will be connected across the full supply voltage and the total current drawing of the remote schema will be about 18mA. The voltage drop across R5 will be now about 1.8V and the window comparator will switch off D2 and will drive D1. The battery will last very long because the schema will be mostly in the off state. Current is needed only for a few seconds when P1 is pushed to check the water-level and one of the LEDs illuminates.
Parts:
R1 = 15K 1/4W Resistors
R2 = 15K 1/4W Resistors
R3 = 1K 1/4W Resistors
R4 = 1K 1/4W Resistors
R5 = 100R 1/4W Resistor
R6 = 47K 1/4W Resistor
R7 = 3.3K 1/4W Resistors
R8 = 3.3K 1/4W Resistors
R9 = 2.7K 1/4W Resistors
R10 = 15K 1/4W Resistors
R12 = 15K 1/4W Resistors
R13 = 3.3K 1/4W Resistors
R14 = 2.7K 1/4W Resistors
R15 = 2.7K 1/4W Resistors
D1 = 3mm Green LED
D2 = 3mm Yellow LED
D3 = 3mm Red LED
C1 = 470nF 63V Polyester or Ceramic Capacitor
J1 = Two ways output sockets
J2 = Two ways output sockets
P1 = SPST pushbutton
B1 = 9V PP3 Battery
Q1 = BC547 45V 100mA NPN Transistor
IC1 = 4012 Dual 4 input NAND gate IC
IC2 = LM393 Dual Comparator IC
Two steel rods of appropriate length
Notes:
  • The two steel rods must be supported by a small insulated (wooden) board
  • IC1 and R1-R4 are mounted on a small board placed near or on the steel rods support
  • The two-wire cable connecting the remote schema board to the main control board, i.e. J1 to J2, can be of any size and type (preferably thin for obvious reasons). It can be very long, if necessary.
  • The schema can be used also with non-metal tanks, provided a third steel rod having the height of the tank will be added and connected to pin #7 of IC1, R3, R4 and J1.
  • The 4012 chip was chosen because it contains two gates and was at hand, but you can use two of the gates contained into 4001, 4011, 4093, 4049, 4069 etc. chips, provided all inputs of each gate are tied together and all inputs of unused gates are connected to the positive rail, leaving output pins open.
Read More..

Monday, August 11, 2014

Water Level Alarm

Water Level Alarm schema diagram
More explanation about water level schema, please go to this page.

Description:
This schema will trigger with any fluid with a resistance under 900K between the maximum separation distance of the probes. Let me explain further. The schema uses a 4050B CMOS hex buffer working on a 5 volt supply.
Read More..